AQ25142B Aquatrol Boiler Reset Control Panel with DHW priority for 4 zones of pumps or 2-wire valves
Part No. AQ25142B
Our Price: $378.00
The AQ251 family of AQUATROL Boiler Reset Controls provides simplified, energy-efficient outdoor temperature compensated control of single temperature, residential hydronic heating systems. The AQ251 easily converts a single zone heating system into a room-by-room comfort control system, or upgrades a basic, relay-logic zoning system to intelligent Zone of Greatest Demand control with outdoor reset for in-creased energy efficiency with reduced boiler cycling. AQ251 boiler controls can ensure ample supply of hot water for both space heating and priority generation of domestic hot water for bathing, dishes and laundry.
• Use with AQ1000 2-wire
polarity-insensitive communicating thermostats (AQ25142B and AQ25144B)
or dry contact thermostat (AQ2511B0, AQ25142B, and AQ25144B).
• 0-10 Vdc modulating output for driving a modulating/condensing boiler.
• Displays outdoor temperature on all AQ1000 thermostats when used with an AQ12C10 outdoor sensor (included).
• Intuitive
programming interface and armchair programming (can be programmed at
your desk and taken to the job site "ready-to-install")
• Customizable control settings and schedules allow for greater level of control and comfort.
• Central programming of zone set points and setback.
• 1- or 2-stage zoning.
• Zoning
Control for up to four zones as shipped; can be expanded to a total of
16 zones with AQ255 or AQ257 expansion zoning panels, and up to 64
zones by using AQ254 Add-a-Temperature expansion panels.
• Outdoor temperature compensation (reset), or Load reset based on indoor temperature feedback.
• Zone synchronization through Zone of Greatest Demand control.
• Domestic hot water priority and priority override protection.
• Line or low-voltage output for zoning equipment (pumps or valves).
• Boiler short cycling protection.
• Boiler post purge.
• Freeze protection.
• Pump/valve exercise.
• Boiler shock prevention from cold water returning to boiler.
• Automated test and purge feature for quick start-up and simplified troubleshooting.
• Integral 38 VA transformer with self resetting electronic fuse.
• 2 hour power supply (super-capacitor) to retain day and time settings during power outage.
• Non-volatile EPROM memory retains program settings during power outage.
| Application |
Boiler reset control for hydronic zoning system |
|
Thermostat Compatibility |
AQ1000 Series 2-wire communicating thermostats and most digital thermostats |
|
Setback Program |
7 day, up to 2 setback periods/day. |
|
User Interface (Setting, Programming) |
LCD Display and a 7 button Key Pad |
|
Number of Communicating Zones Controlled |
4 |
|
Boiler (Supply) Max. Control Temperature (F) |
OFF, 120F to 225 F |
|
Boiler (Supply) Max. Control Temperature (C) |
OFF, 49C to 107 C |
|
Boiler Min. Control Temperature (F) |
OFF, 59F to 180F |
|
Boiler Min. Control Temperature (C) |
OFF, 15C to 82C |
|
Outdoor Low Design Control Temperature (F) |
-60F to 32F |
|
Outdoor Low Design Control Temperature (C) |
-51 C to 0 C |
|
Return Min. Control Temperature (F) |
80 F to 180 F |
|
Return Min. Control Temperature (C) |
27C to 82C |
|
Boiler Differential |
2F to 41F (1C to 23C), or Auto (minimum 2 minutes on time) |
|
Boiler Heat Post Purge |
Off, 10 seconds to 30 minutes (factory default is 30 seconds) |
|
Pump/Valve exercise |
30 seconds per 2 weeks of space heating inactivity |
|
R-C Output (on transformer) |
38 VA, 24 Vac Class II |
|
R-C Input (on Control and Zoning Modules) |
24 Vac Class II (input on Control and Zoning Modules) |
|
Supply/Return Sensor |
Lead
Length: 10 ft. (3050 mm). 10 kilohm NTC thermistor at 25 C (77 F) +/-
0.5F (+/-0.3C) up to 500 ft (150 M) using 18 AWG or larger wire,
beta=3892. |
|
Auxiliary (Demand) Input |
External dry contacts connection only |
|
Heat Demand (Thermostat R-W) Input |
External dry contacts connection only |
|
DHW Demand Input |
External dry contacts connection only |
|
Boiler (T-T) Output Rating |
24 Vac, 0.5A, 12VA |
|
Auxiliary Low Voltage Output Rating |
24 Vac, 0.5A, 12VA |
|
B-B Communication Bus Terminals |
Low voltage, Class II, 2-wire polarity-insensitive, digital communicating link to other Control or Zoning modules. |
|
Zone Module Thermostat input |
Low voltage, Class II, 2-wire polarity-insensitive, digital communicating with power link to AQ1000 series thermostat. |
|
Boiler Pump Output Rating |
120 Vac/250 Vac 5A, 1/3HP |
|
DHW Pump/Valve Output Rating |
120 Vac/250 Vac 5A, 1/3HP |
|
Auxiliary Pump Output Rating |
Dry contact output, 120 Vac/250 Vac 5A, 1/3 HP |
|
Zone Output Contact Rating |
Pumps: 120 Vac/250 Vac, 5A, 1/3 HP |
|
Zone Output Contact Rating |
Valves: 24 Vac, 0.5 A, 12 VA |
|
Control and Zoning Panel Temperature Rating (F) |
32 F to 130 F |
|
Control and Zoning Panel Temperature Rating (C) |
0 C to 55 C |
|
Operating Humidity Range (% RH) |
5 to 90% RH, non-condensing |
|
Sensor Temperature Rating (F) |
-58 F to +230 F |
|
Sensor Temperature Rating (C) |
-50 C to +110 C |
|
Dimensions (in.) |
16 1/2 in wide x 8 in. high x 3 3/8 in deep |
|
Dimensions (mm) |
42 cm wide x 20.3 cm high x 8.5 cm deep |
|
Tradeline Value |
Tradeline |
|
Type of Zoning Devices Controlled |
Pumps or 2-wire valves |
|
Boiler Design Temperature (F) |
80F to 210F |
|
Boiler Design Temperature (C) |
26C to 99C |
|
WWSD (Warm Weather Shut Down) Temperature (F) |
Off, 35 F to 100 F |
|
WWSD (Warm Weather Shut Down) Temperature (C) |
Off, 1 C to 38 C |
|
Electrical Connections (Line Voltage) |
Wire-clamp screw terminals, Maximum 2 x 14 AWG each on line voltage terminals |
|
Outdoor Sensor |
Lead
Length: 10 ft. (3050 mm). 10 kilohm NTC thermistor at 25 C (77 F) +/-
0.5F (+/-0.3C) up to 500 ft (150 M) using 18 AWG or larger wire,
beta=3892. |
|
Replacement Parts |
AQ15540B 4-zone pump expansion module |
|
Replacement Parts |
AQ10X38 24 Vac 38 VA transformer |
|
Replacement Parts |
AQ12C10 outdoor sensor |
|
Replacement Parts |
AQ12C11 supply/return/mixed loop sensor |
|
Replacement Parts |
AQ15100B boiler reset module |
|
Approvals, Canadian Standards Association |
Certified, File No. LR76030 |